Interested in real-time dust monitoring? See the page for our new DustScan Cloud

Industries We Work With 

The impacts of dust and air quality affect us all and are concerns for most industrial, commercial and public organistaions. We work in many countries beyond the British and Irish islands from Australia to the USA and Azerbaijan to Portugal. Our clients' activities are equally variable and range from running docks to managing the environmental impacts of steel works and from road construction to running museums.

Many industrial activities produce dust or impact on air quality; others may be adversely affected by neighbours' activities and the public have a direct and often increasing concern with undesirable impacts. It is essential that due consideration is given to the whole network of impacts at the earliest stages of planning as well as during and after implementation. 

DustScanAQ provides consultancy services to a wide range of sectors including:

  • Minerals, oil and gas
  • Food and agriculture
  • Transport and infrastructure
  • Planning and development
  • Construction and refurbishment
  • Power generation
  • Recycling and waste management
  • Manufacturing
  • Local and national government
  • Storage and warehousing
  • Docks, harbours and marinas
  • Public institutions - schools, hospitals etc.


     

Workplace Dust, Diesel Emissions, Weld Fume, VOC and Isocyanate Exposure Assessment

Location: Northampton                                                         Client: Fusion Building Systems

Background

DSAQ were approached by a manufacturing company specialising in the production of pre-insulated cold-roll steel framed building wall and floor panels. The company occupied a large factory building that housed production/assembly lines, automatic welding and hot-wire cutting machinery and an expanded polystyrene (EPS) production plant. Employees of the company had raised concerns relating to their occupational exposure to dust and fumes. Exposure to substances including dusts and fumes in a place of work relates to the HSE Control of Substances Hazardous to Health (COSSH) 2002 (as amended) regulations. Exposure to lead fumes relates to the HSE Control of Lead at Work (CLAW) 2002 regulations.

Identification of risks

Following a review of the factory Material Safety Data Sheets (MSDS) and after gaining an understanding of the manufacturing site processes through conversations with the factory Health and Safety Manager, DSAQ consultants were able to identify the likely exposure risks and potentially harmful materials:

  • Inhalable dust including wood and EPS dust – from cutting timber frames, orientated strand board (OSB) and EPS;
  • Diesel engine exhaust emissions (DEEE) including CO2 and respirable dust – from forklift truck and HGV emissions;
  • Weld fumes including fumes from a suite of metals and metallic compounds (some potentially carcinogenic) – from the welding activities;
  • Volatile organic compounds (VOC) including pentane – used in EPS production; and
  • Isocyanate (including diphenylmethane diisocyanate (MDI)) fumes – found in adhesives and OSB.
Monitoring

DSAQ conducted inhalable and respirable dust, CO2, metal weld fume, VOC and MDI sampling following MDHS 14/4 guidelines where appropriate and utilised accredited partner laboratories where necessary for specific sample analyses. Both factory staff and representative working areas were monitored using personal sampling equipment and hand-held PID and gas sensors. The factory was fully operational during the exposure survey and staff were undertaking typical manufacturing duties. During the survey DSAQ consultants made observations on factory processes, staff behaviours and existing control measures etc.

Concentrations of the target aerosols were compared to COSHH workplace exposure limits (WELs) listed in EH40/2005 and the CLAW lead occupational exposure limit (OEL).

Results

The inhalable dust levels recorded were well below the WEL for inhalable dust and wood dust. Both the respirable dust and carbon dioxide concentrations recorded were well below their respective WELs, suggesting that DEEE fumes were not a cause for concern. Metal weld fumes were detected but individual metal concentrations were either below their limit of detection or well below their respective WELs. VOC levels were well below the WEL for pentane. MDI was not detected in the two samples tested.

The results of the exposure assessment suggested that the existing dust and fume local exhaust ventilation (LEV) exposure controls employed by the manufacturing company were adequate and no additional measures were deemed necessary.

Client feedback

“Many thanks for the report, which is exactly what we were looking and hoping for… the report appears very good indeed”.
D. Bayliss, Fusion Building Systems.

 

DustScanAQ would be pleased to hear from you if you would like to discuss your requirements and how we can help you with your project, please contact us on 01608 810110 or email info@dustscan.co.uk.